Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Authors’ Reply
BRIDGING THE GAP
BRIEF COMMUNICATION
BRIEF REPORT
Case Report
Case Reports
CME
CME ARTICLE
CME articles - Practice points
COMMENTARY
CONFERENCE REPORT
CONTROVERSY
Correspondence
Correspondences
CUTANEOUS PATHOLOGY
DRUG REVIEW
E-CHAT
Editorial
EDITORIAL COMMENTARY
ERRATUM
ETHICAL HOTLINE
ETHICS
Field: Evolution of dermatologic surgergy
FOCUS
FROM THE ARCHIVES OF INDIAN JOURNAL OF DERMATO SURGERY
From the Editor's Desk
FROM THE LITERATURE
GUEST EDITORIAL
Guidelines
Images in Clinical Practice
Images in Dermatosurgery
INNOVATION
Innovations
INVITED COMMENTARY
JCAS Symposium
LETTER
Letter to Editor
Letter to the Editor
LETTERS
Message from the President
NEW HORIZON
Original Article
Practice Point
Practice Points
PRESIDENTIAL SPEECH
QUIZ
RESEARCH ARTICLE
Resident’s Page
Review
Review Article
Review Articles
SHORT COMMUNICATION
Spot the Diagnosis [Quiz]
STUDY
SURGICAL PEARL
SYMPOSIUM
Symposium—Lasers
Symposium: Hair in Dermatology
Symposium: Lasers Review Article
View Point
VIEWPOINT
VIEWPOINTS
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Authors’ Reply
BRIDGING THE GAP
BRIEF COMMUNICATION
BRIEF REPORT
Case Report
Case Reports
CME
CME ARTICLE
CME articles - Practice points
COMMENTARY
CONFERENCE REPORT
CONTROVERSY
Correspondence
Correspondences
CUTANEOUS PATHOLOGY
DRUG REVIEW
E-CHAT
Editorial
EDITORIAL COMMENTARY
ERRATUM
ETHICAL HOTLINE
ETHICS
Field: Evolution of dermatologic surgergy
FOCUS
FROM THE ARCHIVES OF INDIAN JOURNAL OF DERMATO SURGERY
From the Editor's Desk
FROM THE LITERATURE
GUEST EDITORIAL
Guidelines
Images in Clinical Practice
Images in Dermatosurgery
INNOVATION
Innovations
INVITED COMMENTARY
JCAS Symposium
LETTER
Letter to Editor
Letter to the Editor
LETTERS
Message from the President
NEW HORIZON
Original Article
Practice Point
Practice Points
PRESIDENTIAL SPEECH
QUIZ
RESEARCH ARTICLE
Resident’s Page
Review
Review Article
Review Articles
SHORT COMMUNICATION
Spot the Diagnosis [Quiz]
STUDY
SURGICAL PEARL
SYMPOSIUM
Symposium—Lasers
Symposium: Hair in Dermatology
Symposium: Lasers Review Article
View Point
VIEWPOINT
VIEWPOINTS
View/Download PDF

Translate this page into:

COMMENTARY
6 (
1
); 33-34

Commentary on the Article, “Efficacy and Safety of 10 600-nm Carbon Dioxide Fractional Laser on Facial Skin with Previous Volume Injections”

Dr. Dhepe's Skin City, Post Graduate Institute of Dermatology, Pune, India

Address for correspondence: Dr. Niteen V Dhepe, Medical Director, Dr. Dhepe's Skin City, Post Graduate Institute of Dermatology, Pune, India. E-mail: niteendhepe@gmail.com

Read COMMENTARY-ARTICLE associated with this -

Licence

This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Disclaimer:
This article was originally published by Medknow Publications & Media Pvt Ltd and was migrated to Scientific Scholar after the change of Publisher.

In this issue, Josiane et al. reported use of fractional CO2 laser on facial skin after previous volume injections.[1] This commentary aims at emphasising on the depth of filler placement relative to dermal thickness and depth of ablative plus coagulative column of fractional CO2 laser and variability in this penetration depth with various makes of CO2 lasers.

Arlette, et al. studied the anatomical depth of fillers placed and the thickness of dermis with histopathology study. Average thickness of dermis was 1.37 mm with a range of 1.04-1.86 mm at nasolabial fold. The average depth of filler placement was 2.11 mm, ranging up to 3-4 mm and below. Very little filler was found in the upper dermis of most of the patients.[2]

Understanding of laser tissue interaction of CO2 laser revolves around the concept of ablation or vaporisation, where the target reaches more than 100°C, and coagulation or thermal damage, where the tissue heats up for less than 100°C. As per Goldman,[3] one of the pioneers of ultrapulse wave technology, for a water-containing complex tissue model like skin, the critical fluence of vaporisation (ablation) is 5 J/cm2 delivered as a single shot in less than 100 μsec. Low-power machines achieve this by delivering a train of pulses of lower fluences. These pulse profiles are popularly known as chopped CW, Superpulse and Ultrapulse [Figure 1]. Ratio of ablation to coagulation and that of width to depth of ablative column are the crucial factors in laser tissue interaction of these lasers, apart from fluence.

Pulse profile of CW, Superpulse and Ultrapulse CO2 laser
Figure 1
Pulse profile of CW, Superpulse and Ultrapulse CO2 laser

While considering a previously filler injected patient, for fractional CO2 laser, two research queries arise: Whether the fractional CO2 laser ablation (and/or coagulation) column reaches the depth at which the fillers are placed (2 mm and below), and if it reaches, whether it has any biological effect on stability of the fillers.

We will first address the first query whether CO2 laser can really reaches the depth of filler placement. Active FX (Ultrapulse, Lumenis, Santa Clara, CA, USA) used in the said study at 125 mJ fluence achieves a depth of 112 μ (0.11 mm) of ablation and around 100-200 μ of coagulation (total 300 μ), while Deep FX at 15 mJ fluence achieves 450 μ (0.45 mm) depth of ablation and around 300-800 μ more coagulation below the base (total 1 mm). These are the data on Lumenis white paper.[4] These depths are well within the upper dermis and not enough to make significant alteration in fillers usually placed in deep dermis and below.

But is it true in all situations? It is true only with the parameters under study here. But in practice, more aggressive parameters are commonly used. Active FX at 200 mJ reaches 0.24 mm, while Deep FX at 35-40 mJ fluence that is commonly used for deep scars reaches up to 1.2 mm. The company has come up with a new module called SCAAR FX (Synergistic Coagulation and Ablation for Rejuvenation) that starts with 60 mJ fluence and a penetration of 1.8 mm. Its maximum penetration claimed is 3-4 mm and is used for hypertrophic scars. Using SCAAR FX off-label for acne scars is a common practice. To these depths of ablation of 1-3 mm, add a variable zone of coagulation or thermal damage and a still wider zone of inflammation. The sum of ablation, coagulation and inflammation will be the effective impact zone of fractional CO2 laser. Unfortunately, width of the coagulation zone around the ablative column is either not well studied or differs with the make of the machine.

Hence, a word of caution before we jump to the conclusion that fractional CO2 lasers are safe to use after fillers, as CO2 fractional ablative depth could be anything from 0.1 to 3 mm.

The second query, i.e., whether fractional CO2 laser alters the properties of previously placed filler, will again have two variables: Direct damage with ablation reaching tissue temperature >100°C, and extended damage with coagulation and inflammation. Direct ablation will depend upon the depth of penetration, as discussed above. Coagulation component (and subsequent level of inflammation) depends upon the peak power of machine, pulse profile and distance between two fractional ablative columns (density). As a rule of thumb, higher fluence should always go with lower density, so that heat is not built up in the tissue.[5] To summarise, more coagulation is more inflammation. Whether this inflammation translates into alteration of quality of placed filler is another research question that underlines the need of future larger studies.

The third point of caution is that these proportions of ablation to coagulation and width to depth change considerably with pulse profile (CW, Superpulse and Ultrapulse) and peak power of machine. Unfortunately, parameters discussed in the article on Ultrapulse Deep FX and Active FX may not be translated in the same face value with other machines.

The present study underlines the safety of using fractional CO2 laser in ultrapulse mode with moderate parameters in previously injected patients, while one has to be again careful while using more aggressive parameters. Lastly, we would like to remind the tetrad of safe use of CO2 laser-pulse profile ultrapulse (Superpulse and above), high-power device, low density, and moderate fluence to keep the ablation depth to around 1-1.5 mm.

Source of Support: Nil.

Conflict of Interest: None declared.

REFERENCES

  1. , , , , , . Efficacy and safety of 10,600-nm carbon dioxide fractional laser on facial skin with previous volume injections. J Cutan Aesthet Surg. 2013;6:30-2.
    [Google Scholar]
  2. , , . Anatomic location of hyaluronic acid filler material injected into nasolabial fold: A histologic study. Dermatol Surg. 2008;34:S56-63.
    [Google Scholar]
  3. , . Cutaneous and cosmetic laser surgery. (1st ed). Philadelphia, PA: Mosby Elsevier; . p. :58-76.
    [Google Scholar]
  4. , , , , , , . Lumenis ultrapulse: Physician recommended parameters, Lumenis product guide. Santa Clara CA USA 2012
    [Google Scholar]
  5. , , , , , , . Prospective direct comparison study of fractional resurfacing using different fluences and densities for skin rejuvenation in Asians. Lasers Surg Med. 2007;39:311-4.
    [Google Scholar]

    Fulltext Views
    55

    PDF downloads
    96
    View/Download PDF
    Download Citations
    BibTeX
    RIS
    Show Sections