Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Authors’ Reply
BRIDGING THE GAP
BRIEF COMMUNICATION
BRIEF REPORT
Case Report
Case Reports
Case Series
CME
CME ARTICLE
CME articles - Practice points
COMMENTARY
CONFERENCE REPORT
CONTROVERSY
Correspondence
Correspondences
CUTANEOUS PATHOLOGY
DRUG REVIEW
E-CHAT
Editorial
EDITORIAL COMMENTARY
ERRATUM
ETHICAL HOTLINE
ETHICS
Field: Evolution of dermatologic surgergy
FOCUS
FROM THE ARCHIVES OF INDIAN JOURNAL OF DERMATO SURGERY
From the Editor's Desk
FROM THE LITERATURE
GUEST EDITORIAL
Guidelines
Images in Clinical Practice
Images in Dermatosurgery
INNOVATION
Innovations
INVITED COMMENTARY
JCAS Symposium
LETTER
Letter to Editor
Letter to the Editor
LETTERS
Message from the President
NEW HORIZON
Original Article
Practice Point
Practice Points
PRESIDENTIAL SPEECH
QUIZ
RESEARCH ARTICLE
Resident’s Page
Review
Review Article
Review Articles
SHORT COMMUNICATION
Spot the Diagnosis [Quiz]
STUDY
SURGICAL PEARL
SYMPOSIUM
Symposium—Lasers
Symposium: Hair in Dermatology
Symposium: Lasers Review Article
View Point
VIEWPOINT
VIEWPOINTS
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Authors’ Reply
BRIDGING THE GAP
BRIEF COMMUNICATION
BRIEF REPORT
Case Report
Case Reports
Case Series
CME
CME ARTICLE
CME articles - Practice points
COMMENTARY
CONFERENCE REPORT
CONTROVERSY
Correspondence
Correspondences
CUTANEOUS PATHOLOGY
DRUG REVIEW
E-CHAT
Editorial
EDITORIAL COMMENTARY
ERRATUM
ETHICAL HOTLINE
ETHICS
Field: Evolution of dermatologic surgergy
FOCUS
FROM THE ARCHIVES OF INDIAN JOURNAL OF DERMATO SURGERY
From the Editor's Desk
FROM THE LITERATURE
GUEST EDITORIAL
Guidelines
Images in Clinical Practice
Images in Dermatosurgery
INNOVATION
Innovations
INVITED COMMENTARY
JCAS Symposium
LETTER
Letter to Editor
Letter to the Editor
LETTERS
Message from the President
NEW HORIZON
Original Article
Practice Point
Practice Points
PRESIDENTIAL SPEECH
QUIZ
RESEARCH ARTICLE
Resident’s Page
Review
Review Article
Review Articles
SHORT COMMUNICATION
Spot the Diagnosis [Quiz]
STUDY
SURGICAL PEARL
SYMPOSIUM
Symposium—Lasers
Symposium: Hair in Dermatology
Symposium: Lasers Review Article
View Point
VIEWPOINT
VIEWPOINTS
View/Download PDF

Translate this page into:

Review Article
11 (
3
); 105-109
doi:
10.4103/JCAS.JCAS_102_18

Objective Quantification of Liposuction Results

Division of Plastic and Reconstructive Surgery, McGill University, Montreal, Quebec, Canada
Faculty of Medicine, McGill University, Montreal, Quebec, Canada
Department of Anesthesia and Experimental Surgery, McGill University, Montreal, Quebec, Canada

Address for correspondence: Dr. Mirko Gilardino, Division of Plastic and Reconstructive Surgery, H. B. Williams Craniofacial and Cleft Surgery Unit, The Montreal Children’s Hospital, McGill University Health Centre, 1001 Decarie Boulevard, B05.3310, Montreal, Quebec H4A 3J1, Canada. E-mail: mirko.gilardino@mcgill.ca

Licence

This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.

Disclaimer:
This article was originally published by Medknow Publications & Media Pvt Ltd and was migrated to Scientific Scholar after the change of Publisher.

Abstract

Currently, no reliable gold standard exists for the objective outcome measurement following liposuction. The purpose of this systematic review was to summarize reported methods of monitoring liposuction results by objectively measuring subcutaneous adipose tissue. A systematic literature search was performed to identify relevant articles that described techniques for objectively quantifying adipose tissue following traditional liposuction. The search included published articles in three electronic databases—Ovid MEDLINE, Embase, and PubMed. Subcutaneous adipose tissue was estimated using the following techniques: ultrasound, dual-energy X-ray absorptiometry, magnetic resonance imaging, computed tomography, and three-dimensional imaging volumetric analysis. Reported benefits of liposuction objective measurements included providing patients with a quantitative assessment of the liposuction results pre- and postoperatively, detecting significant changes in body fat deposits, and following patterns of fat redistribution. This review provides a summary of various techniques for quantification of liposuction results. More studies are needed to study the clinical relevancy and impact of the various imaging modalities reviewed as well as to develop automated volumetric measurement technology with improved accuracy, efficacy, and reproducibility.

Keywords

Adipose tissue
liposuction
quantification
volume Keymessage: Currently, no reliable gold standard exists for the objective outcome measurement following liposuction. This review provides a summary of various techniques for quantification of liposuction results. The preliminary results from this review are promising, and we believe that three-dimensional representation and objective quantification are the future of cosmetic surgery.

INTRODUCTION

Liposuction is the second most commonly performed cosmetic surgical procedure in the United States (US), second only to breast augmentation.[1] In 2016, more than 230,000 liposuction procedures were performed in the US alone, amounting to US$1.3 billion.[1] This popularity is partly because of its ubiquitous application in plastic surgery and the reliability of its use.[2] Despite the popularity of this procedure, very few surgeons objectively quantify liposuction results. Surgeons rely mainly on visual inspection through photographs, waist circumference (measuring tape), or through skin-pinch measurements.[23456] The aforementioned techniques may not accurately reflect surgical results as subcutaneous adipose tissue (SAT) is composed of heterogeneous deposits.[7] Currently, no reliable gold standard exists to objectively measure changes following liposuction. The purpose of this systematic review was to summarize reported methods of monitoring liposuction results by objectively measuring SAT.

MATERIALS AND METHODS

A search of the Ovid MEDLINE, Embase, and PubMed databases was performed starting from database establishment to August 1, 2017. Different spellings and versions of the following keywords were searched: (“volume” or “objective” or “quantification” or “measurement” or “mapping” or “representation” or “distribution”) and (“adipose tissue” or “fat”) and “liposuction”. Citations were limited to human studies published in the English language. Studies were retained if they included objective measurement of adipose tissue following liposuction. Skin calipers and waist circumference measures were excluded. Cadaver studies, animal studies, case series (n < 10), abstracts, and review articles were excluded. Studies with combined abdominoplasty and liposuction as well as studies that reported liposuction for non-cosmetic purposes (i.e., lipedema, lipodystrophy, lipomatosis, lymphedema, etc.) were also excluded. All noninvasive techniques for lipolysis and body contouring, ultrasound-assisted, and laser-assisted liposuction were also excluded. Studies were only included if the entirety of the adipose tissue treated was suctioned and available for potential measurement. Two independent reviewers assessed the eligibility of the studies using strict inclusion/exclusion criteria. Studies were selected based on the relevance of the title and/or abstract of retrieved records [Figure 1]. The initial screen excluded studies with evidently irrelevant titles or abstracts. If content was unclear in the initial screen based on abstract review, a formal article review was undertaken. Additional studies were identified from an extensive manual Internet search and from the reference list of relevant articles. The systematic review followed the guidelines provided by the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement.[8]

Flow diagram of systematic review study selection and eligibility
Figure 1
Flow diagram of systematic review study selection and eligibility

ETHICAL APPROVAL

Ethical approval was not required as this was a systematic review. We have followed the World Medical Association’s Declaration of Helsinki.

RESULTS

A total of 1192 studies were identified and further narrowed to 82 potentially eligible studies after primary review. A total of seven studies met the inclusion criteria and were included in this review. Objective measurement of SAT was carried out using the following techniques: ultrasound,[29] dual-energy X-ray absorptiometry (DXA),[51011] magnetic resonance imaging (MRI),[11] computed tomography (CT),[12] and three-dimensional (3D) imaging volumetric analysis[4] [Table 1].

Table 1 Summary of studies that performed objective measurement of adipose tissue following liposuction

DISCUSSION

Ultrasound

Ultrasound has been used in abundance to measure SAT. Due to its relative affordability, accessibility, and radiation-free and high-resolution studies, ultrasound is a powerful tool.[237131415] The accuracy of ultrasound-measured adipose tissue has proven to highly correlate with MRI[161718] and CT.[1920] Ultrasound has been reliably used to quantify tumescent liposuction results.[49] Fat thickness measurement using ultrasound has been described for the thighs, submental, and abdominal regions. In addition to visual inspection, patients can also be provided with quantitative pre- and postoperative assessments of the liposuction results.

Although not included in this review, Toomey et al.[21] and Barton et al.[3] studied the measurement of SAT using ultrasound. The authors observed a significant degree of SAT variation caused by the pressure applied on the ultrasound probe (up to 37%) and proposed a protocol using a force gauge to maintain a fixed amount of pressure on the probe (below 1N) to minimize the compression variability and fat distortion. The authors were able to show a higher correlation between total body fat percentage and ultrasonographic SAT using this protocol. Barton et al.[3] and Leahy et al.[14] subsequently validated the Toomey protocol and assessed its efficacy at measuring SAT reduction after nonsurgical treatment. Barton et al.[3] obtained good reproducibility of SAT measurements (precision of ±0.558mm). One of the challenges encountered was the identification of the deep fascial point (as a reference point for further measurements). This was proven to be more challenging than finding the right pressure to apply on the probe and likely accounted for a small variation in depth measurements. The authors concluded that when the transducer pressure remains below 1N, ultrasound can achieve constant and accurate results in clinically monitoring SAT reduction following nonsurgical fat removal.

Overall, when transducer pressure is controlled, ultrasound can accurately quantify liposuction results in relatively small areas (e.g., submental region). When treating a large surface area (e.g., the abdomen), ultrasound carries the disadvantage of scanning multiple zones because of its relatively narrow field of view and the heterogeneous deposits of adipose tissue.

Dual-energy X-ray absorptiometry

DXA is a tool used to measure body composition using differences in the attenuation of two X-rays as they penetrate tissue[5] and has been shown to provide accurate and objective visual improvement of body composition following liposuction.[51011] Pre- and postoperative DXA scans can be used to measure and compare total fat mass, total lean mass, total bone mineral mass, and body weight. One advantage offered by this modality is the possibility of visualizing the entire body and body fat redistribution patterns. One study[11] showed a significant reduction in body fat following liposuction at 6 weeks and at 6 months, but not at 1 year. In addition, this imaging modality showed remodeling at the hips and thighs and a preferential accumulation of fat in the abdominal region. DXA is a relatively inexpensive, simple, and efficient method of assessing liposuction results using minimal radiation. More studies are needed to confirm its accuracy and reliability in measuring SAT.

Magnetic resonance imaging

The high-quality and radiation-free images of soft tissues obtained using MRI make it a valuable modality to assess SAT.[41618] The cost, time requirements, and limited availability of MRI may restrict its widespread use.[41618] Currently, only one study has reported the use of MRI for objective quantification of liposuction results, more specifically to assess redistribution of subcutaneous and visceral adipose tissue following liposuction.[11] By manually tracing the appropriate borders of muscle and fascia, SAT was distinguished from visceral adipose tissue. Although MRI appears to be accurate and safe for adipose tissue monitoring, restricted access to this costly imaging modality limits its widespread applicability.

Computed tomography

Similar to MRI, CT scans are useful for the simultaneous visualization of subcutaneous and visceral adipose tissues. Currently, only one study has reported the use of CT for objective quantification of liposuction results, more specifically to measure the effect of liposuction and physical activity on visceral fat.[12] The authors found CT-calculated adipose tissue volume to be accurate when compared with aspirated fat volume during liposuction. Despite the availability and accuracy of CT in measuring subcutaneous fat volume, exposure to ionizing radiation remains the main disadvantage.[4161822] CT should be considered when visualization of deeper tissue is required.

Three-dimensional digital photographic imaging system

3D imaging techniques are frequently used in body contouring to assess surface anatomy. Two or more digital cameras rotate around an object and simultaneously take pictures at different angles.[4] An algorithm subsequently uses the data to create a 3D image.[4] The reliability and accuracy of 3D imaging in detecting changes in 3D shape and volume have been validated.[6232425] The low cost and portability of the scanner are unique properties compared to other imaging techniques such as MRI and CT. Although radiographs and CT scans provide pertinent tissue information, their ability to analyze surface anatomy is limited as compared to 3D photogrammetry.

3D digital photographs have been used to follow abdominal volume reduction following liposuction, with high intra-observer reliability (intraclass correlation = 0.985–0.998).[4] One study compared the SAT volume measured by 3D imaging with the volume of aspirated fat (after gravity separation) and found no correlation between the two measurements. The discrepancies between 3D imaging and aspirated fat volume were attributed to varying individual response. Early results of 3D digital photographs are promising. More studies are needed to assess reliability in objectively quantifying changes in abdominal volume after liposuction.

Limitations

The focus of the systematic review was traditional surgical liposuction. Noninvasive techniques were not included. The rational for the above exclusion criteria was to compare estimated SAT volume with actual aspirated volume. Only three studies,[41112] however, compared estimated SAT volume with aspirated fat or with a different imaging modality. Comparison between estimated and aspirated adipose tissue is crucial to validate the accuracy of the various aforementioned methods. Moreover, many studies were missing inter- and intra-observer reliability data, which were essential to support study conclusions and reproducibility.

CONCLUSION

This systematic review provides a summary of various techniques for adipose tissue quantification of liposuction results. Objective measurement of liposuction results has been described using a multitude of techniques. Due to paucity of studies, it is difficult to establish superiority of one technique over another. Individualized decisions should be made with consideration of the potential risks and benefits of the various imaging modalities described. More studies are needed to study the clinical relevancy and impact of the various imaging modalities reviewed as well as to develop automated volumetric measurement technology with improved accuracy, efficacy, and reproducibility. The preliminary results from this review are promising, and we believe that 3D representation and objective quantification is the future of cosmetic surgery.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

REFERENCES

  1. American Society of Plastic Surgeons. In: Plastic surgery statistics report. USA: American Society of Plastic Surgeons; .
    [Google Scholar]
  2. , , , , . Quantitative analysis of liposuction with B mode ultrasound. Aesthetic Plast Surg. 2004;28:226-7.
    [Google Scholar]
  3. , , , , . How should results of nonsurgical subcutaneous fat removal be assessed? Accuracy of B-mode ultrasound. Plast Reconstr Surg. 2016;138:624e-9e.
    [Google Scholar]
  4. , , , , , , . Quantitation of the results of abdominal liposuction. Aesthet Surg J. 2012;32:593-600.
    [Google Scholar]
  5. , , , , , , . Dual-energy X-ray absorptiometry (DEXA): a novel approach for the evaluation of abdominal liposuction results. Aesthetic Plast Surg. 2009;33:235-9.
    [Google Scholar]
  6. , , , , , , . Three-dimensional surface imaging for clinical trials: improved precision and reproducibility in circumference measurements of thighs and abdomens. Lasers Surg Med. 2009;41:767-73.
    [Google Scholar]
  7. , , , , , , . Validation of the measurement of intra-abdominal fat between ultrasound and CT scan in women with obesity and infertility. Obesity (Silver Spring). 2014;22:537-44.
    [Google Scholar]
  8. , , , , . Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. Int J Surg. 2010;8:336-41.
    [Google Scholar]
  9. , , , , , . Evaluation of safety and efficacy of 980-nm diode laser-assisted lipolysis versus traditional liposuction for submental rejuvenation: a randomized clinical trial. J Cosmet Laser Ther. 2016;18:41-5.
    [Google Scholar]
  10. , , , , . Acute and 1-month effect of small-volume suction lipectomy on insulin sensitivity and cardiovascular risk. Int J Obes (Lond). 2006;30:1217-22.
    [Google Scholar]
  11. , , , , , , . Fat redistribution following suction lipectomy: defense of body fat and patterns of restoration. Obesity (Silver Spring). 2011;19:1388-95.
    [Google Scholar]
  12. , , , , , , . Liposuction induces a compensatory increase of visceral fat which is effectively counteracted by physical activity: a randomized trial. J Clin Endocrinol Metab. 2012;97:2388-95.
    [Google Scholar]
  13. , , , , , , . Assessment of measures for abdominal adiposity in persons with spinal cord injury. Ultrasound Med Biol. 2011;37:734-41.
    [Google Scholar]
  14. , , , , , . Ultrasound measurement of subcutaneous adipose tissue thickness accurately predicts total and segmental body fat of young adults. Ultrasound Med Biol. 2012;38:28-34.
    [Google Scholar]
  15. , , , . Validation of ultrasound techniques applied to body fat measurement. A comparison between ultrasound techniques, air displacement plethysmography and bioelectrical impedance vs. dual-energy X-ray absorptiometry. Ann Nutr Metab. 2007;51:421-7.
    [Google Scholar]
  16. , , , , , . Total and segmental subcutaneous adipose tissue volume measured by ultrasound. Med Sci Sports Exerc. 1996;28:908-12.
    [Google Scholar]
  17. , , , , , , . Ultrasound measurements of visceral and subcutaneous abdominal thickness to predict abdominal adiposity among older men and women. Obesity (Silver Spring). 2010;18:625-31.
    [Google Scholar]
  18. , , , , , . Sonographic subcutaneous and visceral fat indices represent the distribution of body fat volume. Abdom Imaging. 2007;32:387-92.
    [Google Scholar]
  19. , , , , , , . Accuracy, reproducibility and repeatability of ultrasonography in the assessment of abdominal adiposity. Acad Radiol. 2011;18:1133-43.
    [Google Scholar]
  20. , , , , , , . Computed tomography-based validation of abdominal adiposity measurements from ultrasonography, dual-energy X-ray absorptiometry and anthropometry. Br J Nutr. 2010;104:582-8.
    [Google Scholar]
  21. , , , , . Technical considerations for accurate measurement of subcutaneous adipose tissue thickness using B-mode ultrasound. Ultrasound. 2011;19:91-6.
    [Google Scholar]
  22. , , , , , , . Sonography detection of small intra-abdominal fat variations. Int J Obes. 1991;15:847-52.
    [Google Scholar]
  23. , , , , . Accuracy and reproducibility of a 3-dimensional stereophotogrammetric imaging system. J Oral Maxillofac Surg. 2010;68:2129-35.
    [Google Scholar]
  24. , , , , , , . Comparison between breast volume measurement using 3D surface imaging and classical techniques. Breast. 2007;16:137-45.
    [Google Scholar]
  25. , , , , , . Validating three-dimensional imaging of the breast. Ann Plast Surg. 2005;54:471-6. discussion 477-8
    [Google Scholar]
Show Sections