Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Authors’ Reply
BRIDGING THE GAP
BRIEF COMMUNICATION
BRIEF REPORT
Case Report
Case Reports
Case Series
CME
CME ARTICLE
CME articles - Practice points
COMMENTARY
CONFERENCE REPORT
CONTROVERSY
Correspondence
Correspondences
CUTANEOUS PATHOLOGY
DRUG REVIEW
E-CHAT
Editorial
EDITORIAL COMMENTARY
ERRATUM
ETHICAL HOTLINE
ETHICS
Field: Evolution of dermatologic surgergy
FOCUS
FROM THE ARCHIVES OF INDIAN JOURNAL OF DERMATO SURGERY
From the Editor's Desk
FROM THE LITERATURE
GUEST EDITORIAL
Guidelines
Images in Clinical Practice
Images in Dermatosurgery
INNOVATION
Innovations
INVITED COMMENTARY
JCAS Symposium
LETTER
Letter to Editor
Letter to the Editor
LETTERS
Message from the President
NEW HORIZON
Original Article
Practice Point
Practice Points
PRESIDENTIAL SPEECH
QUIZ
RESEARCH ARTICLE
Resident’s Page
Review
Review Article
Review Articles
SHORT COMMUNICATION
Spot the Diagnosis [Quiz]
STUDY
SURGICAL PEARL
SYMPOSIUM
Symposium—Lasers
Symposium: Hair in Dermatology
Symposium: Lasers Review Article
View Point
VIEWPOINT
VIEWPOINTS
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Authors’ Reply
BRIDGING THE GAP
BRIEF COMMUNICATION
BRIEF REPORT
Case Report
Case Reports
Case Series
CME
CME ARTICLE
CME articles - Practice points
COMMENTARY
CONFERENCE REPORT
CONTROVERSY
Correspondence
Correspondences
CUTANEOUS PATHOLOGY
DRUG REVIEW
E-CHAT
Editorial
EDITORIAL COMMENTARY
ERRATUM
ETHICAL HOTLINE
ETHICS
Field: Evolution of dermatologic surgergy
FOCUS
FROM THE ARCHIVES OF INDIAN JOURNAL OF DERMATO SURGERY
From the Editor's Desk
FROM THE LITERATURE
GUEST EDITORIAL
Guidelines
Images in Clinical Practice
Images in Dermatosurgery
INNOVATION
Innovations
INVITED COMMENTARY
JCAS Symposium
LETTER
Letter to Editor
Letter to the Editor
LETTERS
Message from the President
NEW HORIZON
Original Article
Practice Point
Practice Points
PRESIDENTIAL SPEECH
QUIZ
RESEARCH ARTICLE
Resident’s Page
Review
Review Article
Review Articles
SHORT COMMUNICATION
Spot the Diagnosis [Quiz]
STUDY
SURGICAL PEARL
SYMPOSIUM
Symposium—Lasers
Symposium: Hair in Dermatology
Symposium: Lasers Review Article
View Point
VIEWPOINT
VIEWPOINTS
View/Download PDF

Translate this page into:

LETTERS
4 (
1
); 67-68
doi:
10.4103/0974-2077.79202

Orthopaedic Surgery in a Patient with Metal Sensitivity

Departments of Orthopedic Surgery and Anesthesia, Fortis hospitals, Bannerughatta Road, Bangalore. E-mail:
Licence

This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Disclaimer:
This article was originally published by Medknow Publications and was migrated to Scientific Scholar after the change of Publisher.

Sir,

Cutaneous hypersensitivity to metal is not uncommon, affecting about 10–15% of the population.[14] Dermal contact with metals and ingestion of metals have been reported to cause immune reactions, which may manifest as erythema, itchy papulovesicular eruptions, hives, etc.[510] Metals known to be sensitizers (haptenic moieties in antigens) include beryllium, nickel,[35611] cobalt[11] and chromium. Hypersensitivity to tantalum,[12] titanium[1314] and vanadium[12] has been reported only rarely. When patients with hypersensitivity to metals present for surgery where metallic prostheses are required, problems arise about the choice of the prosthesis. We present a case of a patient with proven metal sensitivity to cobalt, chromium, nickel and molybdenum, who required bilateral total knee replacement for osteoarthritis and was successfully managed by a titanium prosthesis.

A Caucasian lady aged 65 years, with severe osteoarthritis in both the knees requiring bilateral total knee replacement presented at our institution for receiving the bilateral knee prosthesis. The patient had previous history of allergic reaction to metal buttons in her garments, wrist watch, and metallic jewellery. She also had persistent wound discharge after ankle surgery following a fracture of the ankle a decade ago. The fracture site had earlier been fixed using plates made up of stainless steel (cobalt, chromium and nickel). Following this surgery, the persistent operative wound discharge led to the removal of the prosthesis. Subsequently, testing for allergy to metals was performed by the MELISA® test, which is a blood test to measure Type-IV delayed hypersensitivity reaction (by lymphocyte transformation) to the conventionally used metals such as nickel, chromium, cobalt and molybdenum.

The MELISA test in the patient revealed strongly positive allergy to nickel and chromium and weakly positive results for cobalt and molybdenum. Based on the MELISA report, the implant to be used in our patient was chosen to be of titanium (femoral and tibia component) and a polyethylene insert was used to avoid the possible metal allergy. Since the commonly used prostheses are made up of cobalt, a completely titanium LCS total knee prosthesis (Depuy®) had to be specially procured [Figure 1] for the patient. Bilateral total knee replacement was performed in two surgeries staggered over 4 days. The patient was discharged a week later without any problems.

Titanium total knee prosthesis used in the patient
Figure 1
Titanium total knee prosthesis used in the patient

The case demonstrates the importance of metal allergy in patients undergoing metal prosthetic surgery. All metals in contact with biological systems undergo corrosion. This electrochemical process leads to the formation of metal ions, which may activate the immune system.[15] If cutaneous signs of an allergic response appear after the implantation of a metal device, metal sensitivity should be considered. In the absence of signs and symptoms mentioned above, as in our patient, nonhealing of a postoperative wound in the absence of infection should raise doubts of metal allergy. The testing for delayed-type hypersensitivity for such patients can be conducted either in vivo by skin testing (patch testing or intradermal testing) or in vitro by lymphocyte transformation testing and leukocyte migration inhibition testing using the patient’s blood. Titanium appears to offer the least allergic profile in comparison to other metals and was therefore chosen in our patient. The impurities in titanium might induce allergies at times, although rare.

Our case demonstrated the need for proper investigation with tests such as MELISA and also the need for proper history in all such patients.

REFERENCES

  1. , , , , , . Nickel, cobalt and chromium in consumer products: A role in allergic contact dermatitis? Contact Dermatitis. 1993;28:15-25.
    [Google Scholar]
  2. , , . Metal sensitivity in patients treated for tibial fractures with plates of stainless steel. Acta Orthop Scand. 1977;48:245-9.
    [Google Scholar]
  3. , . Nickel sensitivity and the implantation of orthopaedic prostheses. Contact Dermatitis. 1993;28:257-9.
    [Google Scholar]
  4. , , . Immune response to synthetic materials: Sensitization of patients receiving orthopaedic implants. Clin Orthop. 1996;326:71-9.
    [Google Scholar]
  5. , , , , . Nickel release from nickel-plated metals and stainless steels. Contact Dermatitis. 1994;31:249-55.
    [Google Scholar]
  6. , , , , , , . Nickel release from metals, and a case of allergic contact dermatitis from stainless steel. Contact Dermatitis. 1994;31:299-303.
    [Google Scholar]
  7. , . Orthopaedic biomaterials in research and practice. New York: Churchill Livingstone; .
    [Google Scholar]
  8. , , , , , , . Metal release in patients with loose titanium alloy total hip replacements. Transactions of the Fourth World Biomaterials Congress. Berlin: European Society for Biomaterials; . p. :266.
  9. , , , , , , . Systemic distribution of metal degradation products from titanium alloy total hip replacements: An autopsy study. Trans Orthop Res Soc. 1994;19:838.
    [Google Scholar]
  10. , . Systemic effects of biomaterials. Biomaterials. 1984;5:11-8.
    [Google Scholar]
  11. , , . Cross-reactivity to metal compounds studied in guinea pigs induced with chromate or cobalt. Acta Derm Venereol. 1994;74:341-3.
    [Google Scholar]
  12. , . Organ-specific therapeutic intervention. In: , , , eds. Metal toxicology. San Diego: Academic Press; . p. :71-110.
    [Google Scholar]
  13. , , , , , , . Sensitivity to titanium: A cause of implant failure. J Bone Joint Surg Br. 1991;73:25-8.
    [Google Scholar]
  14. , , , . Titanium dermatitis after failure of a metal-backed patellas. Am J Knee Surg. 1993;6:129-31.
    [Google Scholar]
  15. , , , . Metal sensitivity in patients with orthopaedic implants. J Bone Joint Surg Am. 2001;83:428-36.
    [Google Scholar]

Fulltext Views
147

PDF downloads
166
View/Download PDF
Download Citations
BibTeX
RIS
Show Sections