Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Authors’ Reply
BRIDGING THE GAP
BRIEF COMMUNICATION
BRIEF REPORT
Case Report
Case Reports
Case Series
CME
CME ARTICLE
CME articles - Practice points
COMMENTARY
CONFERENCE REPORT
CONTROVERSY
Correspondence
Correspondences
CUTANEOUS PATHOLOGY
DRUG REVIEW
E-CHAT
Editorial
EDITORIAL COMMENTARY
ERRATUM
ETHICAL HOTLINE
ETHICS
Field: Evolution of dermatologic surgergy
FOCUS
FROM THE ARCHIVES OF INDIAN JOURNAL OF DERMATO SURGERY
From the Editor's Desk
FROM THE LITERATURE
GUEST EDITORIAL
Guidelines
Images in Clinical Practice
Images in Dermatosurgery
INNOVATION
Innovations
INVITED COMMENTARY
JCAS Symposium
LETTER
Letter to Editor
Letter to the Editor
LETTERS
Message from the President
NEW HORIZON
Original Article
Practice Point
Practice Points
PRESIDENTIAL SPEECH
QUIZ
RESEARCH ARTICLE
Resident’s Page
Review
Review Article
Review Articles
SHORT COMMUNICATION
Spot the Diagnosis [Quiz]
STUDY
SURGICAL PEARL
SYMPOSIUM
Symposium—Lasers
Symposium: Hair in Dermatology
Symposium: Lasers Review Article
View Point
VIEWPOINT
VIEWPOINTS
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Authors’ Reply
BRIDGING THE GAP
BRIEF COMMUNICATION
BRIEF REPORT
Case Report
Case Reports
Case Series
CME
CME ARTICLE
CME articles - Practice points
COMMENTARY
CONFERENCE REPORT
CONTROVERSY
Correspondence
Correspondences
CUTANEOUS PATHOLOGY
DRUG REVIEW
E-CHAT
Editorial
EDITORIAL COMMENTARY
ERRATUM
ETHICAL HOTLINE
ETHICS
Field: Evolution of dermatologic surgergy
FOCUS
FROM THE ARCHIVES OF INDIAN JOURNAL OF DERMATO SURGERY
From the Editor's Desk
FROM THE LITERATURE
GUEST EDITORIAL
Guidelines
Images in Clinical Practice
Images in Dermatosurgery
INNOVATION
Innovations
INVITED COMMENTARY
JCAS Symposium
LETTER
Letter to Editor
Letter to the Editor
LETTERS
Message from the President
NEW HORIZON
Original Article
Practice Point
Practice Points
PRESIDENTIAL SPEECH
QUIZ
RESEARCH ARTICLE
Resident’s Page
Review
Review Article
Review Articles
SHORT COMMUNICATION
Spot the Diagnosis [Quiz]
STUDY
SURGICAL PEARL
SYMPOSIUM
Symposium—Lasers
Symposium: Hair in Dermatology
Symposium: Lasers Review Article
View Point
VIEWPOINT
VIEWPOINTS
View/Download PDF

Translate this page into:

Innovations
10 (
1
); 49-50
doi:
10.4103/0974-2077.204584

Spring-loaded Syringe for Multiple Rapid Injections

Department of Dermatology, Venereology and STD, PSG Institute of Medical Sciences and Research, Coimbatore, Tamil Nadu, India
Department of Applied Sciences, PSG College of Technology, Coimbatore, Tamil Nadu, India

Address for correspondence: Dr. CR Srinivas, Department of Dermatology, Venereology and STD, PSG Institute of Medical Science and Research, Coimbatore - 641 004, Tamil Nadu, India. E-mail: srini_cr_1955@rediffmail.com

Licence

This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.

Disclaimer:
This article was originally published by Medknow Publications & Media Pvt Ltd and was migrated to Scientific Scholar after the change of Publisher.

Abstract

Mesotherapy refers to multiple injections of small quantity of the drug over a large area. The mesoguns available are expensive and the motor-driven models tends to waste the expensive material to be injected since the plunger stops after injecting without recoil. We searched for a less expensive device which would inject like the mesogun and still not waste the solution. On searching the web, we identified a spring-loaded syringe. We describe the assembly and use of this inexpensive syringe for delivering multiple injections with minimal wastage.

Keywords

Intralesional injections
mesogun
mesotherapy
platelet-rich plasma
spring-loaded syringe

INTRODUCTION

'Mesotherapy' is a non-surgical, minimally invasive method of drug delivery that consists of multiple intradermal or subcutaneous injections of a mixture of compounds 'melange' in minute doses.[1] It has gained disrepute because of inadequate scientific evidence to prove its efficacy. In spite of this, many new substances such as platelet-rich plasma (PRP), peptides, growth factors and collagen are finding their way to enter the field of mesotherapy.[2] Since small amounts of material have to be injected by multiple pricks rapidly over a large area, mesogun is used. Mesogun is a motor-driven equipment that can be used to rapidly deliver the chemicals into the skin and subcutis. However, most mesoguns are expensive and tend to waste material due to dripping from the needle postulated to be due to rapid withdrawal [Figure 1].[3] While this may not be significant in financial terms when inexpensive substances are injected, products such as PRP or meso solutions for injection which are either expensive or too precious should not be wasted. The cause for dripping is possibly due to lack of minimal recoil, following the injection by the motor-driven plunger. On searching the web, we found a syringe with a spring attached to the piston which would provide the recoil needed to prevent dripping. Since these syringes are not freely available, we modified the available disposable syringe to rapidly deliver small quantity of material into the skin, similar to a mesogun. A 5 ml syringe or an insulin syringe is taken and the piston is removed from the body and a spring which is sterilised using ethylene oxide is inserted onto the piston which is inserted back into the body of the syringe [Figure 2]. The material to be injected is drawn into the syringe and the regular needle is replaced with the Meso needle. The specifics of the spring provided for the purpose of duplication and standardisation used are as follows:

Wastage of injectable material from mesogun
Figure 1
Wastage of injectable material from mesogun
Spring-loaded 5 cc syringes
Figure 2
Spring-loaded 5 cc syringes

Spring for 5 cc syringe

Length – 37 mm, thickness – 1.21 mm, pitch – 4 mm, outer diameter – 15 mm, inner diameter – 12.6 mm, spring constant (k) =1300 N/m.

Spring for insulin syringe

Length – 71.30 mm, thickness – 0.75 mm, spring outer diameter – 5.7 mm, spring inner diameter – 4.58 mm, spring constant (k) =890 N/m.

Spring constant (k) is calculated as follows:

The spring constant of a spring represents the force required to deform it by a certain amount. As most springs obey Hooke's law, the spring constant k is treated as a constant characteristic operational parameter for the spring.

In the case of helical coiled springs, it represents the force required to extend (or compress) the spring by a certain length. It is expressed in N/m. Experimentally, it is measured by fixing it at one end and applying a force 'F' on the other end, along its axis, causing it to extend by a length x. The spring constant is then calculated by the formula:

k = F/x

F is expressed in Newton and x is in metres. Then, k is expressed in N/m.

With this syringe, small quantities of material can be injected by first piercing the needle into the tissue, pressing the piston using the thumb and removing the thumb which results in the recoil of the piston; the syringe is withdrawn from the skin, following which the next site is injected [Video 1]. Before disposal of the syringe, the spring can be removed and retained for reuse after sterilisation. The approximate cost of the spring-loaded syringe would be 30 INR for the 5 cc syringe and 26 INR for the 1 cc syringe. The cost of the reusable spring is 15 INR. Thus the modified spring loaded syringe can be an efficient, cost effective method of drug delivery for mesotherapy and intralesional injections.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

Video available on: www.jcasonline.com

REFERENCES

  1. , , , , , , . Mesotherapy – A non-surgical cosmetic medicine treatment: A review. Int J Pharm Sci Rev Res. 2010;4:45-7.
    [Google Scholar]
  2. , , . Mesotherapy: What is new? Indian J Dermatol Venereol Leprol. 2013;79:127-34.
    [Google Scholar]
  3. , , , , . Evaluation of mesotherapy as a transdermal drug delivery tool. Skin Res Technol. 2016;22:158-63.
    [Google Scholar]
Show Sections