Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Authors’ Reply
BRIDGING THE GAP
BRIEF COMMUNICATION
BRIEF REPORT
Case Report
Case Reports
Case Series
CME
CME ARTICLE
CME articles - Practice points
COMMENTARY
CONFERENCE REPORT
CONTROVERSY
Correspondence
Correspondences
CUTANEOUS PATHOLOGY
DRUG REVIEW
E-CHAT
Editorial
EDITORIAL COMMENTARY
ERRATUM
ETHICAL HOTLINE
ETHICS
Field: Evolution of dermatologic surgergy
FOCUS
FROM THE ARCHIVES OF INDIAN JOURNAL OF DERMATO SURGERY
From the Editor's Desk
FROM THE LITERATURE
GUEST EDITORIAL
Guidelines
Images in Clinical Practice
Images in Dermatosurgery
INNOVATION
Innovations
INVITED COMMENTARY
JCAS Symposium
LETTER
Letter to Editor
Letter to the Editor
LETTERS
Message from the President
NEW HORIZON
Original Article
Practice Point
Practice Points
PRESIDENTIAL SPEECH
QUIZ
RESEARCH ARTICLE
Resident’s Page
Review
Review Article
Review Articles
SHORT COMMUNICATION
Spot the Diagnosis [Quiz]
STUDY
SURGICAL PEARL
SYMPOSIUM
Symposium—Lasers
Symposium: Hair in Dermatology
Symposium: Lasers Review Article
View Point
VIEWPOINT
VIEWPOINTS
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Authors’ Reply
BRIDGING THE GAP
BRIEF COMMUNICATION
BRIEF REPORT
Case Report
Case Reports
Case Series
CME
CME ARTICLE
CME articles - Practice points
COMMENTARY
CONFERENCE REPORT
CONTROVERSY
Correspondence
Correspondences
CUTANEOUS PATHOLOGY
DRUG REVIEW
E-CHAT
Editorial
EDITORIAL COMMENTARY
ERRATUM
ETHICAL HOTLINE
ETHICS
Field: Evolution of dermatologic surgergy
FOCUS
FROM THE ARCHIVES OF INDIAN JOURNAL OF DERMATO SURGERY
From the Editor's Desk
FROM THE LITERATURE
GUEST EDITORIAL
Guidelines
Images in Clinical Practice
Images in Dermatosurgery
INNOVATION
Innovations
INVITED COMMENTARY
JCAS Symposium
LETTER
Letter to Editor
Letter to the Editor
LETTERS
Message from the President
NEW HORIZON
Original Article
Practice Point
Practice Points
PRESIDENTIAL SPEECH
QUIZ
RESEARCH ARTICLE
Resident’s Page
Review
Review Article
Review Articles
SHORT COMMUNICATION
Spot the Diagnosis [Quiz]
STUDY
SURGICAL PEARL
SYMPOSIUM
Symposium—Lasers
Symposium: Hair in Dermatology
Symposium: Lasers Review Article
View Point
VIEWPOINT
VIEWPOINTS
View/Download PDF

Translate this page into:

Innovations
13 (
3
); 257-258
doi:
10.4103/JCAS.JCAS_31_20

Intraoperative Electrosurgical Depilation of a Skin Graft

Division of Dermatologic Surgery, Department of Dermatology, Icahn School of Medicine at Mount Sinai, New York, USA

Address for correspondence: Danielle P. Dubin, 234 E 85th Street, 5th Floor, New York, 10028, USA. E-mail: DPDubin121@gmail.com

Licence

This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.

Disclaimer:
This article was originally published by Wolters Kluwer - Medknow and was migrated to Scientific Scholar after the change of Publisher.

Abstract

Abstract

Full-thickness skin grafts harvested from hair-bearing areas may negatively impact cosmetic outcomes if the recipient site is hairless. Intraoperative depilation of unwanted hair follicles using an electrosurgical device can permanently remove hair with a single treatment and improve overall cosmesis.

Keywords

Electrolysis
hair removal
Mohs micrographic surgery
reconstructive surgery
skin graft

INTRODUCTION

Autologous full-thickness skin grafts can effectively reconstruct large and complex surgical skin defects. The best cosmetic results are obtained when the graft donor site accurately mirrors the color, texture, sebaceous density, and thickness of the recipient site. However, cosmesis may be compromised if unwanted hair from the donor site is transplanted to the recipient site. Traditionally, unwanted skin graft hair is removed using intense pulsed light, lasers, or transcutaneous electrolysis, but these treatments are usually used several months after the graft has matured. Consequently, the patient may have unsightly hair in the interim. These devices also require multiple treatments, which can incur a large cost. At-home patient-directed hair removal methods include plucking, shaving, waxing, or depilatory creams; however, these modalities often yield poor results and must be repeated on a regular basis to sustain optimal cosmetic outcomes.[1]

We report the use of a commonly available electrosurgical device to successfully and permanently remove unwanted hair from a full-thickness skin graft with a single intraoperative treatment.

INNOVATION

A 60-year-old man presented with the reconstructive conundrum of a 6.5 cm × 5.5 cm defect on the left temple following Mohs micrographic surgery of a nodular basal cell carcinoma [Figure 1]. There was insufficient donor skin available on the face to repair the defect. After discussing the risks and benefits, a full-thickness skin graft was harvested from the left hair-bearing skin of the lower abdomen with a total area of 42 cm2 [Figure 2]. Following removal of the subcutaneous fat from the donor skin, all the hair follicles were ablated from the undersurface of the skin using a 30-gauge needle connected to a sharp electrode tip of a monopolar electrosurgical unit at a power of 7 W (Hyfrecator 2000, ConMed, Utica, New York) [Figure 3]. Six months after surgery, there was 100% graft take with no evidence of hair regrowth [Figure 4]. The patient was highly satisfied with the cosmetic result and reported no adverse effects from the surgery or hair removal treatment.

Left temple defect following tumor excision
Figure 1
Left temple defect following tumor excision
Lower abdominal skin graft
Figure 2
Lower abdominal skin graft
Depilation using a 7 W current conducted to the hair follicles via a 30-gauge needle connected to a sharp electrode tip of a monopolar electrosurgical unit at a power of 7 W
Figure 3
Depilation using a 7 W current conducted to the hair follicles via a 30-gauge needle connected to a sharp electrode tip of a monopolar electrosurgical unit at a power of 7 W
100% skin graft take with no evidence of hair reoccurrence, 6 months postoperatively
Figure 4
100% skin graft take with no evidence of hair reoccurrence, 6 months postoperatively

DISCUSSION

Transplantation of terminal hairs to a non-hair-bearing recipient area commonly occurs when a full-thickness skin graft is harvested from the trunk and limbs. It can also occur when a large graft is harvested from the preauricular or postauricular region that includes sideburn or scalp hair. Fortunately, the technique of intraoperative electrolysis of the undersurface of a skin graft is a highly effective, economical, and efficient method for permanently depilating a skin graft. Further studies are needed to assess the use of intraoperative electrolysis for the management of hair-bearing skin grafts.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

REFERENCE

  1. , , , . Terminal hair growth after full thickness skin graft: treatment with normal mode ruby laser. Lasers Surg Med. 2001;28:156-8.
    [Google Scholar]
Show Sections